UPS¶
This is with the UPS APC 700VA BX700U-GR
sudo apt install apcupsd
sudo cp /etc/apcupsd/apcupsd.conf /etc/apcupsd/apcupsd.conf.bak
sudo vi /etc/apcupsd/apcupsd.conf
Notes some of these are just the defaults.
ANNOY 300
ANNOYDELAY 60
BATTERYLEVEL 20
DATATIME 0
DEVICE
EVENTSFILE /var/log/apcupsd.events
EVENTSFILEMAX 10
KILLDELAY 0
LOCKFILE /var/lock
LOGSTATS off
MINUTES 10
NETSERVER on
NISIP 127.0.0.1
NISPORT 3551
NOLOGINDIR /etc
NOLOGON disable
ONBATTERYDELAY 6
POLLTIME 90
PWRFAILDIR /etc/apcupsd
SCRIPTDIR /etc/apcupsd
STATFILE /var/log/apcupsd.status
STATTIME 0
TIMEOUT 0
UPSCABLE usb
UPSCLASS standalone
UPSMODE disable
UPSNAME BX700U
UPSTYPE usb
We also have to edit
sudo vi /etc/default/apcupsd
and there set ISCONFIGURED=yes
. Restart the service after configuration:
sudo systemctl restart apcupsd.service
sudo systemctl status apcupsd.service
The command sudo apcaccess gives a dump of features. Then to test the settings, stop the demon and run
sudo apctest
We still have to test it by pulling the plug.